-
Board Certification
American Board of OphthalmologyPatient Rating
4.9 /5( out of 826 reviews )The patient rating score is an average of all responses on our patient experience survey. The rating averages scores for all questions about care from our providers.
The scale on which responses are measured is 1 to 5 with 5 being the best score.
Patient Comments
Patient comments are gathered from our patient experience survey and displayed in their entirety.
Patients are de-identified for confidentiality and patient privacy.July 31, 2024SOUTH JORDAN HEALTH CENTERGreat care I was very nervous but Dr. Barlow made the procedure so easy!!!!
July 31, 2024MORAN EYE CENTERKick ass doc
July 30, 2024SOUTH JORDAN HEALTH CENTERDr. Barlow was very pleasant and sift spoken and listened to my concerns and addressed them accordingly.
July 25, 2024MORAN EYE CENTERSeemed rushed and said tech would explain other options at next appointment
July 24, 2024MORAN EYE CENTERExtraordinarily intelligent and .accesdible..
July 24, 2024SOUTH JORDAN HEALTH CENTERVery caring and knowledgeable as to my eye issues
July 24, 2024MORAN EYE CENTERDr. Barlow is respectful and explains things well plus he speaks up so that my old ears can hear him.
July 24, 2024MORAN EYE CENTERVery good doctor. Very interested in my care.
July 24, 2024SOUTH JORDAN HEALTH CENTERVery knowledge. Very nice and took his time to explain things.
-
Board Certification and Academic Information
Academic Departments Ophthalmology & Visual Sciences -Primary Board Certification American Board of OphthalmologyEducation history
Residency Ophthalmology - John A. Moran Eye Center, Ï㽶ÊÓƵ of Utah Resident Internal Medicine - Ï㽶ÊÓƵ of Utah Intern Professional Medical Medicine - Medical College of Wisconsin M.D. Speech Communications, Minor: Chemistry - Ï㽶ÊÓƵ of Utah B.A. Selected Publications
Journal Article
- Jensen NR, Ungricht EL, Harris JT, Zaugg B, Barlow WR, Murri MS, Olson RJ, Pettey JH (2023). Temperature Change of Ophthalmic Viscosurgical Devices in a Bi-Chamber Set-Up at a Flow of 0 and 20mL/min. Clin Ophthalmol, 17, 555-560. ()
- Ungricht EL, Harris JT, Jensen NR, Barlow WR, Murri MS, Olson RJ, Pettey JH (2022). Effect of low and passive flow on OVD thermal properties during phacoemulsification. Can J Ophthalmol, 58(6), 507-512. ()
- Peterson JS, Christensen MR, Cooper C, Mamalis C, Bernhisel AA, Zaugg B, Barlow WR, Ungricht E, Olson RJ, Pettey JH (2022). Optimization of Phacoemulsification Tip Gauge on the Oertli CataRhex3 in an in vitro Setting. Clin Ophthalmol, 16, 1091-1097. ()
- Bohner A, Peterson JS, Wright AJ, Mamalis C, Bernhisel A, Zaugg B, Barlow WR Jr, Olson RJ, Pettey JH (2020). Effects on phacoemulsification efficiency and chatter at variable longitudinal ultrasound settings when combined with constant torsional energy. J Cataract Refract Surg, 46(5), 774-777. ()
- Bernhisel AA, Cahoon JM, Sella R, Zaugg B, Barlow WR, Stagg BC, Afshari NA, Olson RJ, Pettey JH (2019). Optimum on-time and off-time combinations for micropulse phacoemulsification in venturi vacuum mode. J Cataract Refract Surg, 45(12), 1797-1800. ()
- Kabbara SW, Heczko J, Ta B, Bernhisel A, Barlow W, Zaugg B, Olson RJ, Pettey J (2019). Impact of torsional micropulse on phacoemulsification efficiency and chatter. Can J Ophthalmol, 54(5), 560-564. ()
- Kabbara SW, Heczko J, Ta B, Bernhisel A, Barlow W, Zaugg B, Olson RJ, Pettey J (2018). Determining optimal ultrasound percent on time with long-pulse torsional phacoemulsification. Can J Ophthalmol, 54(3), 395-398. ()
- Stutz LA, Heczko JB, Bird BA, Thomson RS, Bernhisel AA, Barlow WR, Zaugg B, Olson RJ, Pettey JH (2019). Optimization of the Oertli CataRhex 3® phacoemulsification machine. Clin Ophthalmol, 13, 633-639. ()
- Thomson RS, Bird BA, Stutz LA, Heczko JB, Bernhisel AA, Barlow WR, Zaugg B, Olson RJ, Pettey JH (2019). The effect of increasing power when grooving using phacoemulsification. Clin Ophthalmol, 13, 611-615. ()
- Ha L, Wright A, Wright DD, Bernhisel A, Barlow WR, Pettey JH, Zaugg B, Olson RJ (2019). High vacuum and aspiration on phacoemulsification efficiency and chatter for Centurion. Can J Ophthalmol, 54(1), 136-138. ()
- Boulter T, Bernhisel A, Mamalis C, Zaugg B, Barlow WR, Olson RJ, Pettey JH (2019). Phacoemulsification in review: Optimization of cataract removal in an in vitro setting. Surv Ophthalmol, 64(6), 868-875. ()
- Kabbara S, Heczko JB, Bernhisel AA, Barlow WR, Zaugg B, Pettey JH, Olson RJ (2018). Effect of high vacuum and aspiration on phacoemulsification efficiency and chatter using a transversal ultrasound machine. J Cataract Refract Surg, 44(11), 1378-1383. ()
- Bohner AD, Wright AJ, Ta BT, Bernhisel AA, Zaugg B, Barlow WR, Pettey JH, Olson RJ (2018). Optimum on-time duty cycle for a transversal ultrasound machine. J Cataract Refract Surg, 44(9), 1140-1143. ()
- Bird BA, Thomson RS, Stutz LA, Heczko JB, Bernhisel AA, Barlow WR, Zaugg B, Pettey JH, Olson RJ (2018). Effect of increasing flow when grooving during phacoemulsification. J Cataract Refract Surg, 44(5), 623-626. ()
- Gupta I, Cahoon JM, Gardiner G, Garff K, Henriksen BS, Pettey JH, Barlow WR Jr, Olson RJ (2015). Effect of increased vacuum and aspiration rates on phacoemulsification efficiency. J Cataract Refract Surg, 41(4), 836-41. ()
- Cahoon JM, Gupta I, Gardiner G, Shi D, Zaugg B, Pettey JH, Barlow WR Jr, Olson RJ (2014). Comparison of venturi and peristaltic vacuum in phacoemulsification. J Cataract Refract Surg, 41(2), 428-32. ()
-